Innage Calculation
Where:
H = Gauge reading
H1 = Strapping table gauge, the last entry where H1 < H
H2 = Strapping table gauge, the next entry after H1
X1 = Mass or volume from strapping table corresponding to H1
X2 = Mass or volume from strapping table corresponding to H2
X = Total observed mass or volume for gauge reading
The table below shows strapping table entries for a tank that is measured with an innage strapping table.
Innage Strapping Table Entries
| Height (m) | Volume (m3) |
|---|---|
| 0 | 0 |
| 0.1 | 245 |
| 0.3 | 543 |
| 0.5 | 766 |
| 0.7 | 1020 |
| 1 | 1232 |
| 1.1 | 1343 |
| 1.5 | 1567 |
| 1.8 | 1765 |
| 2.2 | 2121 |
Maximum Volume = 2121 m3
What is the total observed volume for a gauge reading of 2.2m?
This occurs between the 2.0 and 2.3ft gauge entries in the strapping table with the volumes of 705m3 and 1100m3 respectively. So the volume is calculated as follows: