Component Mass Balance - Manifold Example
Mass and component balance is performed on the manifold above with components A, B, C. The measured values and the results are listed in the table below. Notice that a manifold preserves the component fractions from the input to the output flows.
Component Mass Balance - Manifold Example
| Flow | Measurement | Tolerance | Reconciled Value |
|---|---|---|---|
| F1 | 1000 ton | 20 ton | |
| A | 0.7 | .014 | 0.6170 |
| B | 0.3 | 0.006 | 0.2847 |
| C | 0.1 | 0.002 | 0.0983 |
| P1 | 450 ton | 9 ton | |
| A | \<Not Measured> | - | 0.6170 |
| B | \<Not Measured> | - | 0.2847 |
| C | \<Not Measured> | - | 0.0983 |
| P2 | 556 ton | 11.12 ton | |
| A | \<Not Measured> | - | 0.6170 |
| B | \<Not Measured> | - | 0.2847 |
| C | \<Not Measured> | - | 0.0983 |